1-805-484-2992

Quotes - Engineering - Sales

AT150

Mueller
Product Style Ratings Configuration
Heat Exchanger Plate & Frame 350 PSI / 410°F B Frame
AT150 datasheet Download Datasheet

Note: the unit pictured is representative of the standard build and may not exactly depict p/n AT150 as shown on this page.

Mueller AT150

AT150 specifications

Description

Cataloged as AT150, this Accu-Therm plate heat exchanger uses 109-3/8" tall by 34-1/2" wide pressed plates and 8" ports. The gasketed plate pack ranges from 50-3/4" - 176-3/4" in length, delivering approximately 300 - 7,000 sq ft of surface, and it unbolts for inspection and cleaning without cutting pipe. Per-plate surface runs near 11.0 square feet, and the unit handles water flows to about 3200 GPM. Plates are available in 304 or 316 stainless, titanium, and higher alloys; gaskets in NBR, EPDM, and high-temperature EPDM using Clip-In attachment. Frame options include B Frame - for larger units, plates hang from the upper guide bar; capacity to 900 plates. Typical duty is water-to-water HVAC, process cooling, heat recovery, and food and beverage service.

Product Overview

Part Number:
AT150
Series:
Accu-Therm
Brand:
Mueller
Codes & Compliance:
ASME Sec VIII Div 1, CRN, DNV
Also Written:
AT 150, AT-150

Configuration & Size

Surface Area (Sq/Ft):
300 - 7,000 sq ft
Connection Type:
Studded port standard; lap-joint, weld-neck, ferrule, Victaulic
Frame Type:
B | B Frame (Beam)
Max Plate Count:
635 (est.)
Mounting:
Floor mounted frame
Passes:
Single pass standard; multi-pass available
Plate Height:
109-3/8"
Plate Pack Length Range:
50-3/4" - 176-3/4"
Plate Pattern:
Chevron H / V / combination (150X)
Plate Thickness:
0.5 mm standard
Plate Width:
34-1/2"
Port Size:
8"
Wall Construction:
Single wall gasketed
Heat Transfer Area per Plate (Sq/Ft):
11.0 (est.)
Max Flow Rate (GPM):
3200
Performance Rating:
U-value 1,500 BTU/hr-ft²-°F and greater
Performance Rating (Basis):
Clean water-to-water service; 1°F to 3°F approach. Actual duty depends on plate count, pattern, and fluid properties.

Materials of Construction

  • Frame: Painted carbon steel; stainless optional. Zinc-plated compression bolts
  • Gasket: NBR or EPDM standard; High-Temp EPDM, Viton/FKM, Butyl. FDA/3-A
  • Gasket Attachment: Clip-In
  • Plate: 316 SS standard; 304 SS, Titanium, Hastelloy C-276, SMO 254 optional

Rating

  • Max Temperature: 410°F design; 302°F - 329°F gasket limit
  • Max Working Pressure: 350 PSI design
  • Min Temperature: -20°F (MDMT 32°F typical)
  • Test Pressure: 1.3 x MAWP