1-805-484-2992

Quotes - Engineering - Sales

AT40

Mueller
Product Style Ratings Configuration
Heat Exchanger Plate & Frame 350 PSI / 410°F F / B Frame
AT40 datasheet Download Datasheet

Note: the unit pictured is representative of the standard build and may not exactly depict p/n AT40 as shown on this page.

Mueller AT40

AT40 specifications

Description

This AT40 Accu-Therm unit is the gasketed plate-and-frame configuration Mueller builds on the 40 plate. Plate dimensions are 70-1/4" by 27", ports are 4", and the pack length adjusts across 33-7/8" - 159-7/8" to place roughly 99 - 2,292 sq ft of surface into service. Figure about 4.2 square feet per plate and up to 800 GPM on water. Compared with a shell and tube of the same duty, the plate pack occupies a fraction of the floor space and can be reconfigured by adding or removing plates rather than replacing the exchanger. Gaskets use the Loc-In method. Frame styles offered: F Frame - intermediate size, bolted head and tail plate; B Frame - for larger units, plates hang from the upper guide bar; capacity to 900 plates.

Product Overview

Part Number:
AT40
Series:
Accu-Therm
Brand:
Mueller
Codes & Compliance:
ASME Sec VIII Div 1, CRN, DNV
Also Written:
AT 40, AT-40

Configuration & Size

Surface Area (Sq/Ft):
99 - 2,292 sq ft
Connection Type:
Studded port standard; lap-joint, weld-neck, ferrule, Victaulic
Frame Type:
F, B | F Frame (Intermediate), B Frame (Beam)
Max Plate Count:
545 (est.)
Mounting:
Floor mounted frame
Passes:
Single pass standard; multi-pass available
Plate Height:
70-1/4"
Plate Pack Length Range:
33-7/8" - 159-7/8"
Plate Pattern:
Chevron H / V / combination (40MH / 40MV / 40MP)
Plate Thickness:
0.5 mm standard
Plate Width:
27"
Port Size:
4"
Wall Construction:
Single wall gasketed
Heat Transfer Area per Plate (Sq/Ft):
4.2 (est.)
Max Flow Rate (GPM):
800
Performance Rating:
U-value 1,500 BTU/hr-ft²-°F and greater
Performance Rating (Basis):
Clean water-to-water service; 1°F to 3°F approach. Actual duty depends on plate count, pattern, and fluid properties.

Materials of Construction

  • Frame: Painted carbon steel; stainless optional. Zinc-plated compression bolts
  • Gasket: NBR or EPDM standard; High-Temp EPDM, Viton/FKM, Butyl. FDA/3-A
  • Gasket Attachment: Loc-In
  • Plate: 316 SS standard; 304 SS, Titanium, Hastelloy C-276, SMO 254 optional

Rating

  • Max Temperature: 410°F design; 302°F - 329°F gasket limit
  • Max Working Pressure: 350 PSI design
  • Min Temperature: -20°F (MDMT 32°F typical)
  • Test Pressure: 1.3 x MAWP

Quote Request Form:

Questions?

1-805-484-2992